This command configures the IS-IS T2 timer for the specified router process and level.
area_name | Specifies the router process for which the T2 timer configuration applies. |
seconds | Specifies the T2 timer value. The range is 5 to 65535 seconds. |
level | Specifies the IS-IS level to which this timer configuration applies. If neither level 1 nor level 2 is specified, the configuration applies to both levels. |
60 seconds.
The T2 timer is the restart timer for the LSP database for an IS-IS level. If the T2 timer for the respective level expires before the database has been resynchronized, SPF is run for that level.
The following command configures the areax level 1 T2 timer for 90 seconds:
configure isis area areax timer restart 90 level 1
This command was first available in ExtremeXOS 12.1.
This command is available on platforms with a Premier license as described in the Switch Engine v33.1.1 Licensing Guide document.